BTL Polska Sp. z o.o.
BTL Polska Sp. z o.o.
Adres: Leonidasa 49, 02-239 Warszawa
Telefon: 22 667 02 76
WWW: https://www.btlnet.pl/

Podgląd wizytówki
INTIMEX
INTIMEX sp. z o.o. sp. k.
Adres: Egejska 19/39, 02-764 Warszawa
Telefon: +48 22 6687465
WWW: https://intimex.com.pl/

Podgląd wizytówki
Mindray
Mindray Medical Poland
Adres: Cybernetyki 9, 02-677 Warszawa
Telefon: 22 463 80 80
WWW: www.mindray.com

Podgląd wizytówki
Dräger Polska
Dräger Polska Sp. z o.o.
Adres: Posag 7 Panien 1, 02-495 Warszawa
Telefon: 22 243 06 58
WWW: https://www.draeger.com/pl_pl/Home

Podgląd wizytówki
RiCare
RiCare
Adres: ul. Tomasza Zana 39A, 20-634 Lublin
Telefon: +48 81 884 72 79
WWW: https://www.ricare.pl/

Podgląd wizytówki
SONOSCAPE MEDICAL CORP.
SONOSCAPE MEDICAL CORP.
Adres: Guangming District, Guangdong, 518107 Shenzhen
Telefon: +48 784 894 276
WWW: www.sonoscape.com

Podgląd wizytówki
MIRO
MIRO Sp. z o.o.
Adres: Mińska 25B lok U1, 03-808 Warszawa
Telefon: 22 230 20 40
WWW: https://miro-med.pl/

Podgląd wizytówki

Core-Ray Philips CR002-60


Core-Ray Philips CR002-60

Philips CR002-60

Przedłużacze do czujników SpO2.

 

Kompatybilne kardiomonitory:

CR002-6001

  • M1020A, M2475B, M1732A/B, M1722A/B, M1020A, 78833C, 78833A, 78834A, 78352C, 78352A

CR002-6002

  • Philips Medical: M2601A, M3000A, M3500 B, M4735A, MRx, SureSigns VS2, VS3

CR002-6003

  • 78352C, 78354C, 78834C, M1020A, M1025B, M1205A, M1350, M1722A/B, M1732A/B, M2475B, Viridia A1, Viridia A3.

CR002-6005

  • Heartstream XL, Intelliview MP70, M2601A, M3000A, M3500B, M4735A, M1020B, M3000A/M3001A MMS, M3002A MMS X2, M8102A MP2, M8105A MP5, SureSigns VS2, VS3

CR002-6006

  • Philips Medical:M2601A,M3000A,M3500B,M4735A

CR002-6007 (Masimo)

  • Philips SureSigns VS3 monitor etc.

CR002-6008 (Masimo)

  • LNOP

Dostępne modele:

Kod Standard
CR002-6001 Extension cable,8ft,Round 12P>hemicycle 8J, Link to Philips SpO2 sensor
CR002-6002 Extension cable,8ft,hemicycle 8P>hemicycle 8J, Link to Philips SpO2 sensor
CR002-6003 Extension cable,8ft,Round 12P>DB9F, Link to Nellcor SpO2 sensor
CR002-6004 Extension cable,8ft
Hemicycle 8P>
Masimo 6J
Link to Masimo SpO2 sensor
CR002-6005 Extension cable,8ft,hemicycle 8P>DB9F, Link to Nellcor SpO2 sensor
CR002-6006 Extension cable,8ft,
hemicycle 8P>DB9F,
Link to Nellcor Oxi SpO2 sensor
CR002-6007 Extension cable,
8P>DB9F,
Link to Masimo LNCS SpO2 sensor
CR002-6008 Extension cable,
8P>8J,
Link to Masimo LNOP SpO2 sensor
Producent (kompatybilność): Philips Medical
Brak materiałów dodatkowych

Nie wybrano pliku
Maksymalny rozmiar załącznika to 10MB.
Pole zgody na przetwarzanie danych osobowych jest wymagane.
Chcesz poznać ofertę tego produktu? Skontaktujemy Cię z dystrybutorem. Napisz do nas medipment@amdg.net.pl, zadzwoń 663 263 423, lub wybierz czat online w prawym dolnym rogu.