BTL Polska Sp. z o.o.
BTL Polska Sp. z o.o.
Adres: Leonidasa 49, 02-239 Warszawa
Telefon: 22 667 02 76
WWW: https://www.btlnet.pl/

Podgląd wizytówki
INTIMEX
INTIMEX sp. z o.o. sp. k.
Adres: Egejska 19/39, 02-764 Warszawa
Telefon: +48 22 6687465
WWW: https://intimex.com.pl/

Podgląd wizytówki
Mindray
Mindray Medical Poland
Adres: Cybernetyki 9, 02-677 Warszawa
Telefon: 22 463 80 80
WWW: www.mindray.com

Podgląd wizytówki
Dräger Polska
Dräger Polska Sp. z o.o.
Adres: Posag 7 Panien 1, 02-495 Warszawa
Telefon: 22 243 06 58
WWW: https://www.draeger.com/pl_pl/Home

Podgląd wizytówki
RiCare
RiCare
Adres: ul. Tomasza Zana 39A, 20-634 Lublin
Telefon: +48 81 884 72 79
WWW: https://www.ricare.pl/

Podgląd wizytówki
SONOSCAPE MEDICAL CORP.
SONOSCAPE MEDICAL CORP.
Adres: Guangming District, Guangdong, 518107 Shenzhen
Telefon: +48 784 894 276
WWW: www.sonoscape.com

Podgląd wizytówki
MIRO
MIRO Sp. z o.o.
Adres: Mińska 25B lok U1, 03-808 Warszawa
Telefon: 22 230 20 40
WWW: https://miro-med.pl/

Podgląd wizytówki

Cryo Manufacturing Cryomust


Cryo Manufacturing Cryomust

Kriokomora Cryomust

The partial body cabin CRYOMUST has the same design than the CRYOCAB with a laptop control

Main data:

Exclusive patent

Body Slider®

automatic adjustment to the patient size (from 1,50m to 2,20m)

  • Nitrogen extractor located of the patient’s shoulders to prevent any risk of nitrogen breathing.
  • Nitrogen extractor located on the bottom part of the chamber to speed up the nitrogen elimination on doors opening.
  • Built in Oximeter sensor which detects the rate of oxygen in the room and stop automatically nitrogen supply when it goes under 18%.
  • Mobile Oximeter sensor which detects leaks even when the cabin is off.
  • 10 sensors to optimize the cabin safety.
  • Chassis fully made out of stainless steel for an enhanced durability and maximizing the robustness.
  • Laptop dedicated to the cabin control and patient data recording.
  • Diagnosis and Maintenance remote control.
  • Integrated on-board intelligence allowing an accurate handling of the nitrogen injection and control of the sensors

TECHNICAL FEATURES

  • Power: 1,5 kw
  • width: 870 mm
  • Door open: 1 560
  • Length: 1 400 mm
  • Height: 2 160 mm
  • Weight: 250 kg
    Nitrogen consomption during the session at -150°c = around 1 liter per minute

For information, the data consumption of nitrogen depends of the humidity rate in the room. For the design, the CRYOMUST is
delivered either totally white, or white with colored stickers among which a wide choice of colors is offered.

Brak parametrów
Brak akcesoriów

Nie wybrano pliku
Maksymalny rozmiar załącznika to 10MB.
Pole zgody na przetwarzanie danych osobowych jest wymagane.
CRYO MANUFACTURING
77120 Coulommiers, France, 11 B Boulevard de la marne
Telefon: +33 749 23 20 71
E-mail: Wyślij wiadomość
Przedstawiciel:
Lucas Magne
1 produkt w ofercie
Oferta Wyślij zapytanie